OEM/ODM Batteries for Portable Oxygen Concentrators

Large Power is a battery pack manufacturer with its own factory in Dongguan, Guangdong, China. The Hong Kong company is the trading entity. We design OEM/ODM and compatible replacement lithium battery packs for portable oxygen concentrators (POC) used by device brands, private-label programs, distributors, and repair or refurbishment companies.

This page is not a patient store. Large Power does not sell batteries directly to patients. A pack described as compatible with a named concentrator is designed to be evaluated against that platform’s electrical and mechanical interface. It is not an original, genuine, official, or authorized product of that brand.

Founded in August 2002. Typical MOQ is 100–1,000 pieces, depending on pack parameters. Lead time for in-stock standard products can start from 7 days; custom samples typically take 15–45 days. Ask our sales team whether a given POC model is an in-stock standard product.

Project experience: compatible platforms

Large Power has project experience on the platforms below. This is not a claim of mass production, drop-in interchange, or licensed parts. Connector, mechanical lock, and host communication (including any encrypted or vendor-specific handshake) are assessed per project. We do not promise that a compatible pack can always be produced.

OEM battery part numbers, where shown, identify the pack commonly referenced by buyers. They are not Large Power model numbers.

Compatible with / replacement for Commonly cited OEM battery P/N แรงดันไฟฟ้าที่กำหนด Aviation Wh note Fit / communication สถานะ
Compatible with / Replacement for Inogen One G5 and Inogen Rove 6 replaces BA-516 Large Power 41AQ014-02 (14.4V dual pack, 48.24Wh per single pack). The 14.4V 6700mAh pack (04DQ0086-01) is not assigned to this platform. Each 41AQ014-02 pack is 48.24Wh (≤100Wh). These figures are not official Inogen or BA-516 ratings. Assessed per project Project experience. Compatible with Inogen One G5 / Rove 6; replaces BA-516.
Compatible with / Replacement for Inogen One G4 - - Calculate Wh = V × Ah for the approved pack; compare with the 100Wh / 101–160Wh bands below Assessed per project Project experience. Electrical details are evaluated per project.
Compatible with / Replacement for Inogen One G3 - - Calculate Wh = V × Ah for the approved pack; compare with the 100Wh / 101–160Wh bands below Assessed per project Project experience. Electrical details are evaluated per project.
Compatible with / Replacement for Philips SimplyGo - - Calculate Wh = V × Ah for the approved pack; compare with the 100Wh / 101–160Wh bands below Assessed per project Project experience. Electrical details are evaluated per project.
Compatible with / Replacement for CAIRE portable oxygen concentrators - - Calculate Wh = V × Ah for the approved pack; compare with the 100Wh / 101–160Wh bands below Assessed per project Project experience. Name the exact device model in the inquiry.
Compatible with / Replacement for OxyGo portable oxygen concentrators - - Calculate Wh = V × Ah for the approved pack; compare with the 100Wh / 101–160Wh bands below Assessed per project Project experience. Name the exact device model in the inquiry.

การตีพิมพ์ Large Power แพ็ค

Runtime is not listed as a general claim. Runtime depends on the concentrator, delivery setting, compressor load, temperature, and pack age. The ≥400-cycle figure applies only to 41AQ014-02.

Large Power การอ้างอิง แรงดันไฟฟ้าที่กำหนด ความจุ Energy (Wh = V × Ah) FAA band หน้าสินค้าภาษาอังกฤษ หมายเหตุ :
04DQ0086-01, 18650-4S2P 14.4V 6700mAh (6.7Ah) 96.48Wh ≤100 วัตต์ชั่วโมง 14.4V 6700mAh oxygen pack 35.09×80.39×220.69 mm, 550g, charge 0–45°C, discharge −20 to 60°C. This 6700mAh model is not assigned to a named platform. It is a different pack from 33DZ052-01 and from 41AQ014-02.
Company-profile example 14.4V 5200mAh (5.2Ah) 74.88Wh ≤100 วัตต์ชั่วโมง No English product page yet 150×73×21 mm, 399±5g. −40°C to +55°C is the discharge temperature only. Charge temperature, cells, current, communications, enclosure, and part number are not published here.
41AQ014-01 14.4V 7Ah 100.8Wh 101–160Wh No English product page yet A spare pack needs airline approval; passengers may carry at most two spares in this band.
41AQ014-02, dual pack (module A + module B) 14.4V Nominal 3.5Ah / rated 3.35Ah each 48.24Wh each (14.4 × 3.35); rated pair total 96.48Wh Each single pack ≤100Wh (FAA is per battery, not the pair total) Product page coming soon Compatible with Inogen One G5 / Rove 6; replaces BA-516. About 500g and 181.3×82.3×28.7mm per single pack. This is two 3.35Ah modules (pair rated 96.48Wh), not the same pack as 04DQ0086-01 (a single 6.7Ah pack also rated 96.48Wh).

Related ventilator and respirator battery packs

The packs below are for ventilators, respirators, or other breathing machines. They are listed here as related respiratory products. They are not portable oxygen concentrator batteries and should not be selected as POC replacements.

แบตเตอรี่ลิเธียมไอออน 14.8 สำหรับเครื่องช่วยหายใจทางการแพทย์ 4400V 18650mAh

แบตเตอรี่ลิเธียมไอออน 14.8 สำหรับเครื่องช่วยหายใจทางการแพทย์ 4400V 18650mAh

แบตเตอรี่ลิเธียมไอออน 14.8V 4400mAh พร้อมเซลล์ UR18650 ดีไซน์กะทัดรัด 155×75×22 มม. มาตรฐาน GB/T 18287-2000 ที่เชื่อถือได้ จ่ายไฟเสถียรสำหรับอุปกรณ์

แบตเตอรี่ลิเธียม 11.1 2200V 18650mAh สำหรับเครื่องช่วยหายใจ

แบตเตอรี่ลิเธียม 11.1 2200V 18650mAh สำหรับเครื่องช่วยหายใจ

แบตเตอรี่ลิเธียม 11.1V 2200mAh ขนาดกะทัดรัด 71×56×19 มม. การออกแบบ 18650-3S1P ที่เชื่อถือได้ มาตรฐาน GB/T 18287-2000 พลังงานที่เสถียรและจัดเก็บได้อย่างปลอดภัย

เครื่องช่วยหายใจ 10.8V 3180mAh แบตเตอรี่ลิเธียม 18650 แพ็ค 3

แบตเตอรี่ลิเธียม 10.8 สำหรับเครื่องช่วยหายใจ 3180V 18650mAh

แบตเตอรี่ลิเธียมไอออน 10.8V 3180mAh พร้อมเซลล์ NCR18650BD การออกแบบกะทัดรัด 160 กรัม การป้องกัน BMS อัจฉริยะ โซลูชันพลังงานที่เชื่อถือได้สำหรับเครื่องช่วยหายใจ

แบตเตอรี่ลิเธียมไอออนสำหรับเครื่องช่วยหายใจทางการแพทย์ Samsung 10.8V 6.4Ah 18650 แพ็ค 3

แบตเตอรี่ลิเธียมไอออน 10.8 สำหรับเครื่องช่วยหายใจทางการแพทย์ Samsung 6.4V 18650Ah

แบตเตอรี่ลิเธียมสำหรับเครื่องช่วยหายใจทางการแพทย์ 10.8V 6.4Ah ตัวเรือนเกรดอุตสาหกรรม การสื่อสาร SMBus เซลล์ 18650 ที่มีความปลอดภัยสูง พลังงานที่เสถียร และอายุการใช้งานยาวนาน

แบตเตอรี่ลิเธียมสำหรับเครื่องช่วยหายใจ 18650 14.4V 6.7Ah แพ็ค 3

แบตเตอรี่ลิเธียมสำหรับเครื่องช่วยหายใจ 18650 14.4V 6.7Ah

แบตเตอรี่ลิเธียมไอออน 14.4V 6.7Ah พร้อมเซลล์ 18650 การสื่อสาร SMBUS การป้องกัน BMS ขั้นสูง อายุการใช้งานยาวนาน เหมาะสำหรับเครื่องช่วยหายใจและอุปกรณ์การแพทย์แบบพกพา

For medical-system context, see โซลูชันแบตเตอรี่ทางการแพทย์.

FAA / aviation watt-hour bands

Passenger rules for lithium-ion batteries follow FAA PackSafe and 49 CFR 175.10. Airlines and destination authorities may be stricter. This is not an “FAA certification” of the battery pack, and it is not the same as an FAA acceptance label on a complete portable oxygen concentrator.

Lithium-ion pack energy Spare (uninstalled) batteries Installed in a device การอนุมัติสายการบิน
100 วัตต์ชั่วโมง หรือ น้อยกว่า Carry-on only. Terminals must be protected from short circuit. FAA PackSafe does not set a numeric quantity limit for this band, but the batteries must be for the passenger’s use, and many airlines set stricter limits. Allowed in carry-on; checked-baggage conditions are narrower and must be confirmed with the airline (device powered off and protected from accidental activation, and still within the Wh limit). Not required by the FAA Wh band itself
101–160Wh Carry-on only, terminals protected. At most two spare batteries in this band, and airline approval is required. Same Wh band; confirm the airline’s device rule ต้อง
More than 160Wh Not permitted as passenger carry-on or checked baggage Not permitted on passenger aircraft under these passenger exceptions Not applicable — does not travel as a passenger battery

How to calculate energy: Wh = V × Ah. If capacity is printed in mAh, divide by 1,000 first.

ตัวอย่างการใช้งาน Large Power figures, not as official brand-owner ratings:

  • 14.4V × 6.7Ah = 96.48Wh, which is under 100Wh (published pack 04DQ0086-01).
  • 14.4V × 7Ah = 100.8Wh, which is over 100Wh (pack 41AQ014-01). A spare pack at 100.8Wh falls in the 101–160Wh band and needs airline approval; passengers may carry at most two spares in that band.
  • 41AQ014-02 is a dual pack: 14.4V × 3.35Ah = 48.24Wh per module (≤100Wh). FAA watt-hour limits apply to each battery, not to the 96.48Wh pair total.

14 CFR 382.133 allows a U.S. or foreign carrier to require a passenger to bring enough fully charged batteries to power a POC for not less than 150% of the expected maximum flight duration. That is a carrier/passenger rule for device use on board. It is not a battery-factory “FAA certification,” and it does not change the 100Wh / 160Wh bands.

แหล่งที่มา: FAA PackSafe – Lithium Batteries และ 14 382.133 CFR.

เส้นทางการรับรอง

Each item applies at the level shown.

รายการ ครอบคลุมอะไรบ้าง สรุป ความน่าเชื่อถือของ Olymp Trade? Large Power สามารถรองรับได้
ISO.13485 Quality management system for medical devices, at organization / system level Large Power’s quality system is certified to ISO 13485. This is not a product certificate for every pack.
UN38.3 Transport tests for lithium cells and batteries Arranged per model and configuration. Available reports must be checked for the exact pack to be shipped.
IEC 62133 (or IEC 62133-2, depending on the report) Safety of portable sealed secondary cells and batteries Arranged per model where required by the project and target market. Not assumed for every SKU.
IEC 60601-1 Basic safety and essential performance of complete medical electrical equipment Assessed at device level. Large Power can coordinate pack data, protection behavior, and documentation with the device manufacturer. Battery reports do not replace complete-device IEC 60601-1 assessment, FDA marketing authorization, or an FAA acceptance label on the concentrator.

Other marks sometimes requested for a model (CE, RoHS, a generic “IEC” cite) should be discussed against the actual report set for that model. Those marks are not assumed for every SKU.

กระบวนการ OEM/ODM

  1. Share the target platform, voltage window, capacity or Wh target, mechanical envelope, connector, and host-communication needs.
  2. Review cell selection, BMS/protection, enclosure, and whether the design should stay at or below 100Wh.
  3. Build samples (custom samples typically 15–45 days) and support packing, labeling, and test documentation such as UN38.3 or IEC 62133 where required.
  4. Private-label logo, packaging, and instructions are available. We do not print another company’s trademark or imitate an original-brand label.

Why buyers use Large Power for POC packs

  1. B2B OEM/ODM focus — Packs for concentrator brands, private-label programs, distributors, and repairers; not a patient retail store.
  2. Platform evaluation — Compatible mechanical and electrical design is reviewed against the named host. Communication and locking features are confirmed per project.
  3. Aviation Wh review — Energy is calculated as Wh = V × Ah and checked against the 100Wh and 101–160Wh bands.
  4. เส้นทางเอกสาร — Support for UN38.3 and IEC 62133 at pack level, ISO 13485 at quality-system level, and cooperation on complete-device IEC 60601-1.
  5. โรงงานตงกวน — Design and manufacturing at Large Power’s factory in Dongguan, Guangdong; Hong Kong company as the trading entity.
  6. ป้ายกำกับส่วนตัว — Logo, packaging, and instructions without imitating original-brand marks.

Request an OEM/ODM or compatible-pack quotation

Tell us the concentrator platform, the electrical and mechanical targets, annual volume, and the documents you need. We support device brands, private-label programs, distributors, and repair or refurbishment companies. We do not sell batteries directly to patients.

โปรดรวม:

  • Target platform (for example: compatible with / replacement for Inogen One G5) and, if known, the OEM battery part number (for example, replaces BA-516)
  • Nominal voltage, capacity or Wh target, and whether the pack must stay at or below 100Wh
  • Envelope, connector, and any host communication requirement (for example SMBus); note if a handshake still has to be evaluated
  • Annual volume and whether you need private-label packaging
  • Target markets and the document list (UN38.3, IEC 62133, shipping papers, and any device-level support you expect)
  • ตัวอย่างการจับเวลา

MOQ is typically 100–1,000 pieces, depending on pack parameters. Lead time for in-stock standard products can start from 7 days; custom samples typically take 15–45 days.

ลิ้งค์ที่มีความเกี่ยวข้อง

คำถามที่พบบ่อย

ไม่ Large Power sell portable oxygen concentrator batteries directly to patients?

Large Power designs OEM/ODM and compatible replacement packs for portable oxygen concentrators for device brands, distributors, and repair or refurbishment companies; it does not sell batteries directly to patients.

What does “compatible with” a named concentrator mean?

A pack marked compatible with Inogen One G5 is designed to match the electrical and mechanical interface of that platform; it is not an Inogen-branded or Inogen-authorized product. The same applies to other named platforms: a compatible or replacement pack is not an original, genuine, official, or authorized product of that brand. Large Power model 41AQ014-02 is compatible with Inogen One G5 / Rove 6 and replaces BA-516. The 14.4V 6700mAh pack (04DQ0086-01) is not assigned to a named platform.

How do you calculate watt-hours, and why does 7Ah matter?

Watt-hours are calculated as Wh = V × Ah. 14.4V × 6.7Ah = 96.48Wh, which is under 100Wh. 14.4V × 7Ah = 100.8Wh, which is over 100Wh. The 96.48Wh figure is the published Large Power 14.4V 6700mAh pack (04DQ0086-01). The 100.8Wh figure is Large Power pack 41AQ014-01 (14.4V 7Ah); a spare 41AQ014-01 pack is in the 101–160Wh band and needs airline approval. 100.8Wh is not an official original-brand rating. A separate dual-pack, 41AQ014-02, is 14.4V × 3.35Ah = 48.24Wh per single pack, which is under 100Wh per battery. 41AQ014-02 is compatible with Inogen One G5 / Rove 6 and replaces BA-516; the 6700mAh pack is not assigned to that platform.

What are the FAA watt-hour rules for spare lithium-ion batteries?

Under FAA PackSafe rules, spare lithium-ion batteries rated 100Wh or less may be carried in carry-on baggage; batteries from 101 to 160Wh require airline approval, and passengers may carry at most two spares in that band. Spare (uninstalled) lithium-ion batteries must travel in carry-on baggage, not in checked baggage, and the terminals must be protected from short circuit. Lithium-ion packs above 160Wh are not accepted under the passenger exceptions. Airlines and destination authorities may be stricter. A watt-hour calculation is not an FAA certification of the battery, and it is not the same as an FAA acceptance label on a complete portable oxygen concentrator.

What is the 150% battery rule for portable oxygen concentrators?

14 CFR 382.133 allows a U.S. or foreign carrier to require a passenger to bring enough fully charged batteries to power a POC for not less than 150% of the expected maximum flight duration. That is a carrier rule for on-board use of the device. It does not change the FAA PackSafe 100Wh and 160Wh bands, and it is not a battery-factory certification.

Which concentrator platforms does Large Power have project experience with?

Large Power has project experience on packs compatible with Inogen One G5 and Inogen Rove 6, Inogen One G4, Inogen One G3, Philips SimplyGo, CAIRE, and OxyGo portable oxygen concentrators. Fit, connectors, and host communication are evaluated per project, and this list is not a claim that a drop-in pack is already in mass production for every model.

ที่ Large Power POC packs are published today?

The English site currently publishes a 14.4V 6700mAh oxygen-concentrator pack (04DQ0086-01) at 96.48Wh. A 14.4V 5200mAh example in the company profile is 74.88Wh, with a discharge temperature of −40°C to +55°C, and it does not yet have an English product page. 41AQ014-01 is a 14.4V 7Ah pack at 100.8Wh. 41AQ014-02 is a 14.4V dual-pack (modules A and B) at 3.5Ah nominal / 3.35Ah rated per single pack (48.24Wh, about 500g, 181.3×82.3×28.7mm each; 96.48Wh rated for the pair). It is compatible with Inogen One G5 / Rove 6 and replaces BA-516. The 14.4V 6700mAh pack (04DQ0086-01) is not assigned to a named platform.

Which certifications apply, and at what level?

ISO 13485 is a quality-management-system certificate for the organization, not a product certificate for every pack. UN38.3 transport tests and IEC 62133 battery safety tests are arranged per model and must be checked for the exact configuration to be shipped. IEC 60601-1 is assessed at complete medical electrical equipment level; Large Power can support the device manufacturer with pack data and documentation, but a battery report does not replace complete-device assessment.

What are typical MOQ and lead times?

Typical MOQ is 100–1,000 pieces, depending on pack parameters. Lead time for in-stock standard products can start from 7 days, and custom samples typically take 15–45 days. Ask our sales team whether a given POC model is an in-stock standard product.

สามารถ Large Power supply private-label packaging?

ใช่. Large Power can supply private-label logos, packaging, and instructions for B2B programs. We do not print another company’s trademark or imitate an original-brand label.

เลื่อนไปที่ด้านบน

รับใบเสนอราคาฟรีทันที !

แบบฟอร์มขอใบเสนอราคาแบบป๊อปอัพ
หากคุณมีคำถามใด ๆ โปรดอย่าลังเลที่จะติดต่อเรา
โซลูชันแบตเตอรี่แบบกำหนดเองที่เน้นลูกค้า1