Prismatic lithium Ion Battery(NCA103443 /3.6V /2010mAh)
This battery is a lithium-ion rechargeable battery with a nominal voltage of 3.6V and a typical capacity of 2010mAh. It is a medium to small-sized battery and is often used in portable electronic devices such as smart wearables, wireless headphones, small instruments or handheld devices.
It supports charging within the range of 10 to 45℃ and discharging within the range of -20 to 60℃, and has good adaptability to working temperatures. The battery has a low internal resistance (≤100mΩ) and high charging and discharging efficiency, which can ensure stable power supply for the equipment.
| No. | Items | Specifications | Remark |
|---|---|---|---|
| 1 | Typical capacity | 2010mAh | 0.2C Standard discharge |
| Minimum Capacity | 1950mAh | ||
| 2 | Nominal Voltage | 3.6V | Mean Operation Voltage |
| 3 | Delivery voltage | 3.6~3.9V | Within 10 days from Factory |
| 4 | Charge Ceiling Voltage | 4.2V | By standard charge method |
| 5 | Discharge Cut-off Voltage | 2.75V | |
| 6 | Internal Impedance | ≤100mΩ | Internal resistance measured at AC 1KHZ after 50% charge |
| 7 | Charge current | 682mA | 0~+10℃ Standard charge current |
| 1365mA | +10~+45℃ Continuous max charge current | ||
| 8 | Discharge current | 0.2C | -20~+60℃ Standard discharge current |
| 3820mA | 0~+40℃ Continuous max discharge current | ||
| 9 | Operation Temperature and relative humidity Range | Charge: 10~+45℃, RH ≤85% | Discharge: -20~+60℃ |
| 10 | Storage temperature for a long time | <1 month: -10~+45℃, 60±25%RH<3 months: -10~+35℃<6 months: 0~25℃ | |
| 11 | Weight | ≤33.7g |
Test Equipment
(1) Dimension Measuring Instrument
The dimension measurement shall be implemented by instruments with accuracy no less than 0.01 mm.
(2) Voltmeter
Class with national standard or more sensitive class with inner impedance not less than 10 KΩ/V.
(3) Ammeter
Class with national standard or more sensitive class. Total external resistance including ammeter and wire is less than 0.01 Ω.
(4) Impedance Meter
Impedance shall be measured by an AC impedance method (AC 1 kHz LCR meter).
Standard Test Condition
Tests should be conducted with new batteries within one month after shipment from our factory, and the cells shall not be cycled more than five times before the test. Unless otherwise defined, tests and measurements shall be done under a temperature of 25±3℃ and relative humidity of 60±25%.
Standard Charge
0.2C = 402 mA
Full charge condition: At 25±3℃, charge with constant current 0.2C and constant voltage 4.2V until the charge current drops below 0.02C.
Charging time is approximately 6.5 hours.